NKE 1218-K-TV-C3 Pendelkugellager (90x160x30)
Description
â verified catalog valuesAs a self-aligning ball bearing, this bearing compensates for misalignment and shaft deflection. The dynamic load rating of 40.3 kN characterises this bearing. The static load rating is 21.7 kN. The limiting speed is 5300 rpm. This variant features increased radial clearance (C3). If the self-aligning ball bearing is set onto a plain shaft by way of an adapter sleeve, the drive-up distance expands the inner ring â increased clearance (C3) holds the initial play needed for that available.
Increased clearance (C3) has a very concrete reason in this design. Self-aligning ball bearings are frequently supplied with a tapered bore and set onto a plain, unstepped shaft by way of an adapter sleeve â the method with which long shafts are built up in plummer block housings. During drive-up the inner ring is deliberately expanded, and the mounting is controlled by the clearance remaining in the process; without a sufficiently large initial play, too little of it would be left after drive-up.
If too little play remains at the end, the ball set is braced against the raceways; frictional torque and temperature rise, and the additional heat reduces the play further. The larger clearance class changes nothing about the properties of the design: the inner ring unit remains able to swivel in the outer ring, the bearing position compensates for misalignment and shaft deflection, the load rating stays tied to the low conformity of the spherical outer raceway, and axial forces are permissible only to a modest extent.
Rings and balls are made of through-hardened standard bearing steel. The open form presupposes sealing and lubricant supply by the surrounding construction. For the layout, the type of seat, the drive-up distance or fit, and the temperature profile to be expected should be assessed together. Increased radial clearance C3 â Dimensional/form-fit equivalent â verify suffix-level details for critical applications. Matching suffixes are also listed by SKF (HC5C3, HC5C3WT, C3), FAG (C3), NSK (C3), NTN (C3) and NACHI (C3).
NKE 1218-K-TV-C3 Pendelkugellager (90x160x30)
â 90 x 160 x 30 mm
Response within 4 business hours
Cross-brand equivalents
Verified equivalents for 90 Ă 160 Ă 30 mm â live price & availability.
Same dimensions means the same bearing type and matching main dimensions (d Ă D Ă B). Sealing, cage, internal clearance and execution (e.g. material, precision, grease fill) are encoded in the suffix and may differ â please check before ordering. Equivalent additionally means the same sealing, internal clearance and tolerance class; the cage and other suffix features (e.g. lubrication groove) may differ.
| Product | Brand | Match | Price | Availability | ||
|---|---|---|---|---|---|---|
| FAG 1218-K-TVH-C3 Pendelkugellager (90x160x30)Equivalent | FAG | Equivalent | âŹ107.61 | In stock | ||
| SKF 1218 K/C3 Pendelkugellager (90x160x30)Equivalent | SKF | Equivalent | âŹ139.55 | In stock | ||
| NTN 1218 SK Pendelkugellager (90x160x30)Same dimensions | NTN | Same dimensions | âŹ159.59 | In stock | ||
| NKE 1218-K-C3 Pendelkugellager (90x160x30)Equivalent | NKE | Equivalent | âŹ133.14 | In stock | ||
| NKE 1218-K Pendelkugellager (90x160x30)Same dimensions | NKE | Same dimensions | âŹ133.14 | In stock | ||
Frequently asked questions
What are the dimensions of the NKE 1218-K-TV-C3 Pendelkugellager (90x160x30)?
Who is the manufacturer of the NKE 1218-K-TV-C3 Pendelkugellager (90x160x30)?
How heavy is the NKE 1218-K-TV-C3 Pendelkugellager (90x160x30)?
What seal type does the NKE 1218-K-TV-C3 Pendelkugellager (90x160x30) have?
What bearing type is the NKE 1218-K-TV-C3 Pendelkugellager (90x160x30)?
What equivalent bearings are available for the NKE 1218-K-TV-C3 Pendelkugellager (90x160x30)?
Guides for this product
- GuideC3 oder C4 â wann welche Lagerluft?C3 oder C4 Lagerluft? Wann gröĂere Radiallagerluft nötig ist â feste Passung, WĂ€rmedehnung, Temperaturdifferenz â und was die Betriebslagerluft damit zu tun hat.
- GuideWie verĂ€ndert sich die Lagerluft bei ErwĂ€rmung?ErwĂ€rmung verkleinert die Lagerluft. So wird aus der Initiallagerluft das kleinere Betriebsspiel â und so wĂ€hlen Sie die richtige Lagerluftklasse.